IO-Link Master EIP Series EDS Files

Overview

You do not need to add the IOLM 4-EIP, IOLM 8-EIP, or IOLM DR-EIP to Rockwell software for normal IO-Link Master-to-PLC communications. However, you can easily add the IO-Link Master and its associated Electronic Data Sheet (EDS) files to Rockwell software.

The files named IO-Link Master_*.ico are icon files and files named IO-Link Master_dd_NNNN-x.xx.eds are ODVA electronic data sheet files where:

  • dd is the model name

  • NNNN is the product ID number

  • x.xx is the version number

Download the Files

You can download the EDS files provided for the IO-Link Master.

Model SupportedApplication Base VersionFileDescription

IOLM 4-EIP

IOLM 8-EIP

IOLM DR-8-EIP

1.4.xx

v1.04

Download

If you need information about using EDS files, you can refer to the following procedures.

IOLM 4-EIP

IOLM 8-EIP

IOLM 8-EIP-L

IOLM DR-8-EIP

IOLM DR-8-EIP-P

IOLM DR-8-EIP-T

1.5.18

1.5.28

v1.05

Download

If you need information about using EDS files, you can refer to the following procedures.

Configuring RSLinx

  1. Open RSLinx.

  2. If there is not an EtherNet/IP driver already configured, use the following steps:

    1. Under Communications, select Configure Drivers.

    2. Under Available Drivers, select Remote Devices via Linx Gateway.

    3. Select Add New.

    4. Use the default driver name or type your own driver name and click OK to continue.

    5. Select the adapter of the network card that you want to use to communicate with the IO-Link Master and click Ok.

  3. Select RSWho to verify that RSLinx can communicate with the IO-Link Master.

[Note]
Note

A yellow question mark appears by the IO-Link Master(s) in the RSWho window when the associated EDS file(s) are not installed.

Adding EDS Files to Rockwell Software

  1. Open the EDS Hardware Installation Tool. (Select Start > All Programs > Rockwell Software > RSLinx Tools.)

  2. Click Add.

  3. Click Register a directory of EDS files.

  4. Browse to the Comtrol/EtherNetIP directory and click Next to continue.

  5. Verify that there is a green check beside each EDS file name and select Next to continue.

  6. Click Finish to exit.

IO-Link Master Does Not Display

If RSLinx does not display the device after adding IO-Link Master and the EDS files to RSLinx, perform the following procedure:

  1. Select File > Exit and Shutdown to exit and shutdown RSLinx.

  2. Remove the following files from your hard drive:

    • \Program Files\Rockwell Software\RSCOMMON\Harmony.hrc

    • \Program Files\Rockwell Software\RSCOMMON\Harmony.rsh

  3. Restart RSLinx. The IO-Link Master or IO-Link Masters should now appear with the associated icon or icons.


nice color