RocketLinx ES7106-VB Installation Overview

Use the following overview or Quick Installation Guide to install the ES7106-VB.

  1. Set the DIP switch to configure the Port Link Alarm. ES7106-VB Connectors

    The port link failure alarm is applicable when ES7106-VB ports are connected to an auto-negotiation capable 10/100 full-duplex device.

    DIP SwitchStatusDescription
    1 and 2

    ON

    OFF

    Enables the Gigabit port link failure alarm for the corresponding port.

    Disables the Gigabit port link failure alarm for the corresponding port.

    3 through 6

    ON

    OFF

    Enables the PoE port link failure alarm for the corresponding port.

    Disables the PoE port link failure alarm for the corresponding port.

    ES7106-VB DIP Switch

    This table provides information about the DIP switch settings for the ES7106-VB.

    Port G2Port G1Port 1Port 2Port 3Port 4
    DIP 1DIP 2DIP 3DIP 4DIP 5DIP 6
  2. Wire the earth ground.

    To ensure the system is not damaged by noise or any electrical shock, we suggest that you to make an exact connection between the ES7106-VB and earth ground. On the bottom side of the ES7106-VB, there is one earth ground screw. Loosen the earth ground screw with a screw driver; then tighten the screw after the earth ground wire (12 to 24AWG) is connected.

  3. [Note]
    Note

    Power should be disconnected from the power supply before connecting it to the ES7106-VB. Otherwise, your screwdriver blade can inadvertently short your terminal connections to the grounded enclosure.

    Wire the power inputs. The required output voltage is 12-24VDC, which delivers IEEE 802.3af PoE on all PoE ports. ES7106-VB Connectors

    1. Disconnect the terminal block from the ES7106-VB.

    2. Insert the positive and negative wires (12 to 24 AWG) into the V+ and V- contact on the terminal block connector.

    3. Tighten the wire-clamp screws to prevent the DC wires from becoming loose.

    4. Plug the terminal block into the ES7106-VB.

  4. Insert the wires and set the DIP switch using the table (above). After setting the DIP switch to ON, the relay output alarm will detect any power or port failures, and form a short circuit. The alarm relay output is Normal Open.

  5. If desired, mount the unit.

  6. Connect the appropriate Ethernet cables between the ES7110-VB Ethernet ports and the network nodes.

    • Ports G1 and G2 are Gigabit Ethernet uplink ports that support 10BASE-T, 100BASE-TX, and 1000BASE-TX.

    • Ports 1-4 are Fast Ethernet 10/100BASE-TX PoE ports that are IEEE 802.3af (PoE) compliant (15.4W maximum).

    All of the Ethernet ports auto-detect the signal from connected devices to negotiate the link speed and duplex mode. Auto MDI/MDIX allows you to connect another switch, hub, or workstation without changing straight-through or crossover cables. Crossover cables cross-connect the transmit lines at each end to the received lines at the opposite end.

    RJ45 Pin

    10/100BASE-TX PoE

    (Alternative B)

    1000BASE-TX

    Gigabit Uplink

    1RX+BI_DA+
    2RX-BI_DA-
    3TX+BI_DB+
    4Vport+BI_DC+
    5Vport+BI_DC-
    6TX-BI_DB-
    7Vport-BI_DD+
    8Vport-BI_DD-
    Ethernet Cabling

    Always make sure that the cables between the switch and attached devices (for example, switch, hub, or workstation) do not exceed 100 meters (328 feet).

    • 10BASE-T: Category 3, 4, or 5 cable

    • 100BASE-TX: Category 5 cable

    • IEEE 802.3af: Category 5 cable